Main functional features BQZ fire alarm controller (linkage type) has the functions of fire alarm, fire alarm control, gas fire extinguishing control, fault alarm, shielding, supervision, self-test information display and query power supply display software control. Being able to handle quickly when a fire occurs allows fire fighters to take effective and timely treatment of the fire scene when a fire occurs. It can also intelligently monitor on-site fire protection equipment to achieve on-site real-time monitoring.
Functional technical requirements
.Self-test
After the assembly is completed, connect the power to the controller. After the controller enters the normal working interface, enter the function menu for self-test. The indicator lights of each module of the controller should be all Light up.
.Automatic login. When the controller shows that it is working normally, connect a set of corresponding input devices and output devices to any loop and enter the automatic login interface. After the login is completed, go to the loop corresponding to the loop component (No. loop module loop) The relevant information of this group of devices should be able to be queried.
. Linkage programming. Enter the linkage programming interface to perform linkage programming on the group of devices in system linkage and direct linkage respectively. When finished, press the Save button to save.
. Manual automatic selection will manually/automatically select to the automatic state and the automatic indicator light will light up. Disable/allow the selection to the allow state and allow the indicator light to light up.
. The fire alarm test enables the input device to simulate a fire alarm state. The controller should be able to quickly report fire alarm information. The fire alarm indicator light of the controller should light up and be accompanied by a rapid beep.
. After the bus linkage startup controller alarms, the output device should start soon. At the same time, the controller will display relevant information about the startup of the output module. The controller startup indicator light will light up and be accompanied by a prompt sound. At the same time, the corresponding bus linkage button start indicator light of the device lights up. (b) The corresponding direct linkage output start indicator light of the device should light up and at the same time the controller can report the direct linkage equipment start information and there is a D output on the start line terminal of the group of direct linkage equipment output terminals. When the bus linkage stops, press the corresponding bus button input start/stop button. The output device should stop quickly. The controller will display the information that the output device has stopped. The corresponding bus button start indicator light will go out.
. Direct linkage Press the stop button on the corresponding direct linkage operation card. There is a D on the stop line terminal of the output terminal of this group of equipment. When the output is released, the D will disappear and the D on the start line terminal will also disappear. At the same time, the start indicator light on the controller goes out.
. The fault alarm controller can send out a sound and light signal indicating the fault when there are problems such as power failure loop module failure, sound and light output terminal open circuit, detector loss, etc.
?
Product technology and parameters
. Product name fire alarm controller
. Dimensions**
. Product model QZ
. Operating temperature ℃~ +℃
. Relative humidity % (℃℃)
. Working power supply %% Hz
. Power supply available
. The detection bus line system adopts twisted pair reference model R*.
.Standardbr/> Weight
Bus fire alarm controller KTV fire wall-mounted host