Main functional features: B fire alarm controller (linkage type) has fire alarm, fire alarm control, gas fire extinguishing control, fault alarm, shielding, supervision, self-test, information display and query, power display, software control and other functions. When a fire occurs, it can be dealt with quickly, so that firefighting personnel can promptly and effectively deal with the fire scene when a fire occurs. It can also intelligently monitor on-site fire protection equipment to achieve real-time on-site monitoring.
Functional technical requirements
.Self-test
After the assembly is completed, connect the controller to the power supply. After the controller enters the normal working interface, enter the function menu for self-test. The indicator lights of each module of the controller They should all light up.
.Automatic login. When the controller shows that it is working normally, connect a set of corresponding input devices and output devices to any loop. Enter the automatic login interface. After the login is completed, in the loop corresponding to the loop component (No. loop module loop ) should be able to query relevant information of this group of devices.
. Linkage programming. Enter the linkage programming interface to perform linkage programming on the group of devices in system linkage and direct linkage respectively. When finished, press the Save button to save.
. Manual automatic selection will select manual/automatic to the automatic state, the automatic indicator light will light up and prohibit/allow the selection to the allow state, and the allow indicator light will light up.
. The fire alarm test enables the input device to simulate a fire alarm state. The controller should be able to quickly report fire alarm information, and the fire alarm indicator light of the controller should light up and be accompanied by a rapid beep.
. After the bus linkage startup controller alarms, the output device should start soon. At the same time, the controller will display relevant information about the startup of the output module. The controller startup indicator light will light up and be accompanied by a prompt sound. At the same time, the corresponding bus linkage button start indicator light of the device lights up. (b) The corresponding direct linkage output start indicator light of the device should be on, and at the same time, the controller can report the start information of the direct linkage equipment, and there is a D output on the start line terminal of the output terminal of the direct linkage equipment. When bus linkage stops, press the corresponding bus button input start/stop button and the output device will stop quickly. The controller will display the information that the output device has stopped, and the corresponding bus button start indicator light will go out.
. Direct linkage Press the stop button on the corresponding direct linkage operation card. There will be a D output on the stop line terminal of the output terminal of this group of equipment. After releasing, the D will disappear. At the same time, the D on the start line terminal will also disappear. . At the same time, the start indicator light on the controller goes out.
. When the fault alarm controller encounters problems such as power failure, loop module failure, open circuit of the sound and light output terminal, loss of the detector, etc., it can send out sound and light signals indicating the fault.
?
Product technology and parameters
. Product name: Fire alarm controller
. Dimensions: **
. Product model
. Operating temperature: ℃~+℃
. Relative humidity: R (℃℃)
. Working power supply
. Power supply available
. Detection bus wire system: twisted pair, reference model R *.
.Standard
Weight
Intelligent fire alarm system Fire automatic alarm system Fire smoke alarm host